1. The whole machine body is compact, good
rigidity
	 
		2. The controller adopts HRC62, DSP
architecture, stable and reliable, with its own I/O interface, can directly
control the proportional valve.
	
| Model # | DN-25 | DN-35 | DN-50 | DN-80 | DN-100 | DN-125 | DN-150 | DN-200 | |
| Rated Capacity | KVA | 25 | 35 | 50 | 80 | 100 | 125 | 150 | 200 | 
| Power Supply | V/Φ/Hz | 380/1PH/50HZ | |||||||
| Max. Primary Current | A | 65 | 92 | 131 | 158 | 210 | 210 | 263 | 400 | 
| Primary Cable | MM2 | 16 | 16 | 25 | 35 | 50 | 50 | 70 | 120 | 
| Max. Short Circuit Current | KA | 15.5 | 19 | 24 | 25 | 26 | 28 | 34 | 38 | 
| Rated Duty Cycle | % | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 
| Secondary Empty Voltage | V | 4.2 | 5.2 | 6.1 | 7.6 | 8.6 | 9.5 | 11.2 | 13.5/10.5 | 
| Welding Cylinder Size | Φ*L | Φ80*60 | Φ80*60 | Φ100*60 | Φ125*100 | Φ160*100 | Φ160*100 | Φ200*100 | Φ200*100 | 
| Working Pressure | N | 2500 | 2500 | 3900 | 6000 | 10000 | 10000 | 15000 | 15000 | 
| Compressed Air Pressure | MPa | 0.6~0.7 | 0.6~0.7 | 0.6~0.7 | 0.6~0.7 | 0.6~0.7 | 0.6~0.7 | 0.6~0.7 | 0.6~0.7 | 
| Cooling Water Consumption | L/MIN | 6 | 6 | 8 | 8 | 8 | 8 | 10 | 14 | 
| Compressed Air Consumption | L/time | 1.43 | 1.43 | 2.28 | 3.56 | 5.84 | 5.84 | 9.24 | 9.24 | 
| Throat Depth | MM | 382 | 382 | 378 | 543 | 543 | 543 | 543 | 528 | 
| Arm Gap | MM | 333 | 333 | 329 | 364 | 364 | 364 | 364 | 425 | 
| Electrode Size | MM | Φ25 | Φ25 | Φ25 | Φ30 | Φ30 | Φ30 | Φ30 | Φ30 | 
| Dimensions | H(MM) | 1472 | 1472 | 1450 | 1803 | 1803 | 1803 | 1803 | 1803 | 
| L(MM) | 962 | 962 | 965 | 1284 | 1284 | 1284 | 1284 | 1269 | |
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |
| W(MM) | 697 | 697 | 702 | 702 | 702 | 702 | 702 | 848 | |